| Molecular Imaging with Individualized Priors |
|
Vasilis Ntziachristos Background and GoalsProf. Ntizachristos is one of the world leaders in the field of tomographic fluorescence imaging. In his previous position at Mass General Hospital and in his present position as Director of the Institute for Biomedical Engineering at the Technical University of Munich his group builds novel imaging systems, devises and implements novel forward modeling and reconstruction algorithms, and invents and tests an ever expanding range of applications. He also holds an Adjunct Research Professor position and Northeastern University where he is the PI of the NIH grant listed above. He and Prof. Brooks with collaborators have had a productive collaborative relationship for the past five years. Prof. Ntziachritos’ current projects which are of direct relevance to this collaboration with CIBC include:
In all of these applications Prof. Ntziachritos’ team will require computational steps that follow the proposed CIBC imaging pipeline: extraction of models from images, forward simulation to predict measurements (often using finite element methods), comparison of predicted to actual measuremnts to drive a solution to an inverse estimation problem, and adequate visualization all through the process. Collaborator Publications[1] D. Hyde, E. Miller, D.H. Brooks, and V. Ntziachristos. "A statistical approach to inverting the born ratio". IEEE Trans Med Imag, 26(7):893–905, July 2007. [2] D. Hyde, E. Miller, D. Brooks, and V. Ntziachristos. "New techniques for data fusion in multimodal FMT-CT imaging". In Proc. Int. Symp. on Biomed Imaging (ISBI09), Paris, France, May 2008. [3] D. Hyde, R. De Kleine, S. MacLaurin, E. Miller, D. Brooks, T. Krucker, and V. Ntziachristos. "Hybrid FMTCT imaging of amyloid-beta plaques in a murine Alzheimer’s disease model". NeuroImage, 44(4):1304– 1311, February 2009. [4] D. Hyde, R. Schulz, , E. Miller, D. Brooks, and V. Ntziachristos. "Performance dependence of hybrid X-ray CT - FMT on the optical forward problem". JOSA A, 24(4):919–923, February 2009. [5] D. Hyde, E. Miller, D. Brooks, and V. Ntziachristos. "Data specific spatially varying regularization for multimodal Fluorescence Molecular Tomography". IEEE Trans. Med. Imag., 2009. [6] D. Hyde, E. Miller, D. Brooks, and V. Ntziachristos. "Differential equation-driven regularization for joint FMT-CT imaging". In Proc. Int. Symp. on Biomed Imaging (ISBI09), Boston, MA, USA, 2009. [7] D. Hyde, E.L. Miller, D.H. Broks, and V. Ntziachristos. "A statistical method for inverting the born ratio". In Proceedings of the International Symposium on Biomedical Imaging (ISBI), Arlington, VA, USA, April 2006. [8] D. Hyde, R. DeKlein, S.A. MacLaurin, D. Brooks, E.L. Miller T. Krucker, , and V. Ntziachristos. "Hybrid FMT-CT method for in vivo imaging of amyloid plaques in a mouse model for alzheimers disease". In Society for Molecular Imaging Meeting, Providence, RI, USA, September 2007. [9] D.E. Hyde, R. Schulz, E. Miller, D.H. Brooks, and V. Ntziachristos. "Incorporation of structural apriori information in fluorescence molecular tomography". In OSA Biomedical Optics Topical Meeting, St. Petersburg, FL, USA, March 2008. |