| Evaluation of Inverse Solution Approaches |
|
Rok Hren, PhD Institute of Mathematics, Physics and Mechanics, University of Ljubljana, Slovenia. BackgroundThis project stems from the ability of the Center to provide geometric models, validation data, simulation models, and software infrastructure for computing and comparing solution strategies. The first results of this collaboration have been presented at an international conference1 and we intend to expand the scope and depth of the analysis to prepare a journal article and then continue to collaborate with Dr. Hren on numerical aspects of this problem. The goal of the project to date has been to evaluate systematically the performance of different regularization techniques using a realistic human torso model. We wish to compare also the boundary element method (BEM) and finite element method (FEM), two predominant methodologies in computing the geometrical and electrical properties of the torso volume conductor.
GoalsDuring the past 30 years, many research efforts have been devoted to exploring and validating the utility of electrocardiographic imaging, where potential distribution on the epicardial surface is inversely computed from a large number of electrocardiograms measured both on the anterior and posterior torso surface. Given that the electrocardiography community has developed a plethora of regularization techniques to tackle the ill-posedness and to gauge the rapidly oscillating inverse solutions, there is a growing need to compare, structure and unify those diversified regularization methods by using the same volume conductor and the same cardiac source models. The figure shows a small sample of the results from the study in which we compared two of the most promising approaches of computing epicardial potentials from a cage of electrodes surrounding an isolated canine heart in a torso shaped electrolytic tank. The simulation was carried out by the BEM, and the cage potentials were inversely computed by the FTV and STV. The body-surface potentials exhibited initial anterior maximum, resulting from the septal activation of the left ventricle. Both FTV and STV captured well the qualitative features of the cage potentials, with STV providing smoother solutions. The specific aims of this collaboration are as follows:
PublicationsM. Milanic, V. Jazbinsek, D.F. Wang, J.G. Sinstra, R.S. Macleod, D.H. Brooks, and R. Hren. "Evaluation of approaches to solving electrocardiographic imaging problem". In Computers in Cardiology, IEEE Press, 2009. |